| Sign In | Join Free | My burrillandco.com |
|
The HUADA ZMDM-31PWP1 connector redefines compactness. With
dimensions 2.78mm shorter in length, 5.4mm narrower, and 3.9mm
lower than its predecessor (the J29A series), it’s a space-saving
marvel. Whether you’re designing handheld devices, wearables, or
IoT gadgets, this connector ensures efficient use of board real
estate. Its volume reduction by approximately 40% compared to J29A
opens up new possibilities for miniaturized electronics. Plus, the
1.91mm contact spacing and 1.65mm row spacing make it ideal for
densely packed PCBs.
Beyond its size, the ZMDM-31PWP1 shines in reliability. It meets
the GJB2446A standard, making it a trusted choice for rugged
applications. The crimping cross-sectional area accommodates wire
sizes from 0.15mm² to 0.35mm², ensuring secure connections.
Operating between -55°C and +125°C, it withstands extreme
temperatures. With low contact resistance (8 mΩ), mechanical
durability (500 cycles), and pressure resistance (800V), this
connector is your go-to solution for critical systems. Whether
you’re in aerospace, automotive, or industrial electronics, the
HUADA ZMDM-31PWP1 delivers performance without compromise.
Current and Voltage: Nominal Voltage (Un): The ZMDM-31PWP1 operates
within a voltage range of 3 x 220/380 V to 240/415 V (three-phase
four-wire) or 3 x 110/190 V to 133/230 V (three-phase three-wire).
Current Range (Imin/Itr): You can select a current range from 0.25
A to 2.0 A (minimum/transition current).
Frequency (fn): The connector supports both 50 Hz and 60 Hz with a
tolerance of ±2%.
Measurement Accuracy: For active energy measurement (ZMD310AT/CT),
it adheres to EN 50470-3 class B standards.
Reactive energy measurement (ZMD310AT/CT) complies with IEC
62053-23.
Achieves Class 1 accuracy with bridging time data storage.
Power Consumption: Voltage Circuit: Consumes 0.5 W (110 V) or 0.7 W
(240 V).
Current Circuit: Requires only 0.03 VA (10 A).
Additional Features: Energy Direction Detection: Understands energy
flow for efficient monitoring.
Phase Voltage Monitoring: Keeps an eye on phase voltages.
Thermal Short Circuit Protection: Responds swiftly (within ≤ 10 ms)
to protect against short circuits.
Technical Features Table
| Maximum Operating Temperature | +125 °C |
| Minimum Operating Temperature | -55 °C |
| Insulation Resistance | 5000 mΩ |
| Mechanical life | 500 |
| Work pressure | 4.4 KPa |
| Impact | 490m/s2 |
| Vibration | 10-2000Hz 196m/S2 |
| Contact Resistance | 8 mΩ |
| Relative humidity | 40℃, 98% |
| Current | 5 A |
| Pressure Resistant | 800V |
|